What are the recommended procedures for soluble oil systems after shut down?

If you have a period of shutdown, we recommend metalworking fluid users follow the below procedure before production gets underway again.

Our Top Tips for Managing Metalworking Fluid after Shutdown:

  • Skim off any tramp oil – this will allow your coolant to breathe
  • Circulate the fluid for at least an hour
  • Check dilution using a hand refractometer – Aim for the upper of the recommended range – If you’re unsure of the recommended dilution, contact our technical team who can advise
  • Top up fluid accordingly
  • Check pH level – If you get a low pH reading between 8.2 – 8.5 add Biotect @ 0.20% of sump capacity – pH readings below 8.2, a full system sterilization and fluid change is advised
  • Carry out dipslide testing – Refer to HSE MW05 for acceptable levels – Carry out full system sterilizationOur technical team are on hand if you have any questions, or would like some assistance with your metalworking fluid management. Our PROCARE Fluid Management service can include all of the above routine checks, and ensure you are HSE MW05 compliant. Call us on 0114 285 2987 or email us: [email protected]

 